Item
|
Contents
|
|
Input
|
Rated Voltage
|
thee-phase
380V +-15% single-phase 220V +-15%(thee-phase 220V +-15%)
|
|
Rated Frequency
|
50 / 60 Hz(+-5%)
|
|
Output
|
Rated Voltage
|
3-phase 0 ~ 380V; 3-phase 0 ~ 220 V
|
|
Frequency Range
|
0.00 ~ 400.0 Hz (frequency resolution
ratio 0.01Hz)
|
| Overload Capacity |
150% 60S |
|
Control
Mode
|
Frequency
Setting Accuracy
|
Digit
Setting: 0.01Hz Analog Quantity Setting: Max Frequency
x 0.4%
|
| Setting
Mode |
optimized space vector
control |
| V/F
Curve |
3 V/F curves. To select
and set beeline V/F curve, polygonal line V/F curve and
squre V/F curve as per load |
| Torque
Promotion |
Manual setting torque promotion
within 1 ~ 15% |
| Automatic
Voltage Setting |
Automatic setting output
voltage to meet input power fluctuation within certain
range |
| Braking
Mode |
DC Braking+Optimized Energy Braking
|
| PI
Adjusting |
With built-in PI adjuster for automatic
control
|
| Jogging |
Jogging Range: 0.00 ~400.0Hz
|
| Automatic
Circular Running |
User will program output frequency mode
as per process requirements
|
|
Operation Functions
|
Frequency Setting
|
Digit
frequency setting, keypad "UP/DOWN"
keys setting, "UP" and "DOWN"
terminals setting;
Keypad potentiometer or external analog signal (0-10V,
0-20mA) setting;
Analog channel compound operation setting;
Multi-state speed-control and code timing;
485 communication control box / computer setting.
|
|
Start/Stop Control
|
Control over keypad /485 communication
control box, terminals and computer
|
|
Protection Functions
|
Input out-phase, input undervoltage,
over-voltage, over-current, inverter overload, motor
overload, overheat, current check trouble, peripheral
equipment trouble, user password error/exterior interference,
contactor monitoring.
|
|
Display
|
LED nixie tube showing present output
frequency, present rotate-speed, present output current,
present output voltage, final axis linear-velocity,
exterior pulse count-value, types of failure, function-code
parameters and operation parameters;
4 LED indicators showing the current working status
of inverter.
|
|
Environment Conditions
|
Environment Location
|
Free of corrosive gas and dust
|
|
Environment Temperature
|
-10ºC ~ +50ºC
|
|
Environment Humidity
|
< 90 % (no water-bead coagulation)
|
|
Vibration Strength
|
Below <0.5 g (acceleration)
|
|
Applicable
Motor P
|
0.4 ~ 160KW
|